Basics of Working with Unity Pro Mailbox Messaging Error Codes ProSoft Technology Support How to Get Help How to Contact Us: Technical Support When you have completed the steps in this User Manual, you will have learned how to:. To get the most benefit from this User Manual, you should have the following skills:.
Microsoft Windows: Install and launch programs, execute menu commands, navigate dialog boxes, and enter data. The application described in this User Manual requires the following minimum hardware and software components:. Schneider Electric Telemecanique Unity Pro programming software, version 4.
Pentium IV, 2. Automating integration for Schneider Electric SE Modicon processors and maximizing ease-of-use are the hallmark design criteria behind the new ProLinx SE line of communication gateways.
You can import these files into Unity Pro version 4 software without modification, eliminating the need to write additional communication message logic.
Acyclic messaging allows the processor to request extended slave data and diagnostics, as well as access slave-specific special functions. The gateway has an RS serial port. ProSoft Configuration Builder can use this port to view the gateway's diagnostics and troubleshooting menus. You can also use the serial port to upgrade the gateway's firmware. The internal database is central to the functionality of the gateway. This database is shared between all the ports on the gateway and is used as a conduit to pass information from one device on one network to one or more devices on either network supported by the gateway.
This permits data from devices on one communication port or network to be viewed and controlled by devices on another port or network.
In addition to data from the Master port, status and error information generated by the gateway can also be mapped into the internal database. This area is internal addresses through , which have corresponding virtual Modbus addresses of through fivedigit addressing or through six-digit addressing , as shown in the preceding data flow diagram.
The types of acyclic data available varies from slave to slave but generally include such data as alarm and status information, extended diagnostic information, extended process data information, and device-specific special commands. The following illustration shows the basics of acyclic mailbox message data flow from a Modicon processor, through the two gateway drivers, out to PROFIBUS slaves, with responses if any returned to the Modicon.
Your logic will also decide if and when to trigger any acyclic messages you may need to send. To help you create your control and sequencing logic, here are a few principles to keep in mind. The main difference will be that the DFBs to update cyclic data will most likely be triggered much more often than the acyclic DFBs are triggered. Some commands, such as write commands, return only an acknowledgement that the command was received and executed.
Commands sometimes fail. Some acyclic messages return no data. Acyclic messages sometimes fail. All the provided DFBs have internal checks built in to prevent more than one at a time from being active. There is a Message Done bit to indicate the communication cycle completed successfully; and, there is a Message Error bit to indicate the communication cycle did not complete successfully.
Password Protecting the Module Wait for the startup screen to appear. This action opens a Windows Explorer file tree window. This folder contains all of the applications and files you will need to set up and configure your gateway.
EXE " file and follow the instructions on your screen to install the software on your PC. Most of the information needed to help you use ProSoft Configuration Builder is provided in a Help System that is always available whenever you are running ProSoft Configuration Builder. The Help System does not require an Internet connection. ProSoft Configuration Builder PCB provides a quick and easy way to manage gateway configuration files customized to meet your application needs.
PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed known working configurations to new projects. To begin, start ProSoft Configuration Builder. If you have used other Windows configuration tools before, you will find the screen layout familiar. The following illustration shows the ProSoft Configuration Builder window with a new project. This action opens the. At this time, you may wish to rename the "Default Project" and "Default Location" folders in the tree view.
GSD files page Follow these steps to install the GSD file or files for your slave device or devices. GSD files are often both model number specific as well as model revision specific. Just because you may have an older GSD file from a manufacturer for the particular make and model of your slave device does not guarantee it will work for a newer revision of that device. This action opens a dialog box that allows you to browse for the location of the GSD configuration files to install.
Depending on the device and language used in the file, the actual extension may be ". GSD", ". GSE", ". GSS", of other combinations; hence the generic reference to ". If the file already exists in the configuration file path, you will be prompted to overwrite the file. If you have no device-specific bitmap file, you may C ANCEL the bitmap upload, and a generic device icon will be used in the Bus Configuration window for this slave device.
This action opens the Master Properties dialog box. The configuration information. This action adds the slave device and connects it to the Master in a network relationship. This action opens a list of device configuration values. The selections available for other devices may be different, so you should review the specifications for the product you are installing in order to determine the correct values to use.
The slot view displays the slot number, configuration data, and input and output addresses. For this example, we will configure 8 words of input and 32 words of output. These input and output words are assigned to addresses within the gateway's internal database. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source.
Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware. Powered by amikonplc. The primary focus is to provide connectivity solutions that link dissimilar automation products.
ProSoft Technology provides field proven connectivity and communication solutions that bridge between various automation products as seamlessly as if they were all from the same supplier. Send a Message If you have any problem when using the website or our products, please write down your comments or suggestions, we will answer your questions as soon as possible!
Related Products. Have a nice short trip with Amikon team 20 Dec , Subscribe Subscribe to our newsletter and stay up to date with the latest news and deals! Home Products about contact. Allen Bradley IBN. A llen Bradley OBN. Downloading the Sample Program to the Processor Installing ProSoft Configuration Builder Setting Up the Project Setting Module Parameters SIE Client x SIE Client x Commands Configuration Examples Static ARP Table Ethernet Configuration Connecting Your PC to the Module Downloading the Project to the Module Controller Tags Using Controller Tags Controller Tag Overview LED Status Indicators Ethernet LED Indicators Clearing a Fault Condition Connecting to the Module's Web Page The Diagnostics Menu Monitoring Module Information Monitoring Backplane Information Monitoring Database Information Reading Status Data from the Module Status Data Definition Configuration Error Word Client Command Errors Product Specifications General Specifications Functional Specifications Hardware Specifications Backplane Data Transfer Normal Data Transfer Blocks Special Function Blocks Client Driver Client Command List Ethernet Cable Specifications Ethernet Cable Configuration Ethernet Performance Before Beginning Reading the Ethernet Settings from the Module Writing the Ethernet Settings to the Module Reading the Clock Value from the Module Writing the Clock Value to the Module Contacting Technical Support Warranty Information What's New?
To get the most benefit from this User Manual, the following skills will be needed:. The module requires mA of available 5 Vdc power. Other third party applications may have different minimum requirements. Refer to the documentation for any third party applications for system requirements. Note: The module can be installed in a local or remote rack.
Important: Before beginning the installation, please verify that all of the following items are present. If any of these components are missing, please contact ProSoft Technology Support for replacement parts.
Note: If the module is being installed in a remote rack, the Setup pins can be left jumpered. Refer to the Rockwell Automation product documentation for installation instructions.
Warning: All safety instructions must be followed when installing this or any other electronic devices. Failure to follow safety procedures could result in damage to hardware or data, or even serious injury or death to personnel. Refer to the documentation for each device that will be connected to verify that suitable safety procedures are in place before installing or servicing the device. Use the same technique recommended by Rockwell Automation to remove and install ControlLogix modules.
ControlLogix system components can be installed or removed while chassis power is applied and the system is operating. However, please note the following warning. Warning: When the module is inserted or removed while backplane power is on, an electrical arc can occur.
This can cause unintended machine motion or loss of process control. Electrical arcs may also cause an explosion when they happen in a hazardous environment. Verify that power is removed or the area is non-hazardous before proceeding.
Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance that can affect module operation.
The slot in which the module is installed in must be indentified in order for the sample program to work correctly. Slot numbers are identified on the green circuit board backplane of the ControlLogix rack. Note: If the module is inserted improperly, the system may stop working or may behave unpredictably. Note : This section only applies if the processor is using RSLogix version 16 or higher.